How to Size an Off-Grid Solar System

Five steps, one direction: from the load you use to the panels, battery, controller, and inverter that cover it. Here's the whole chain with a worked example.

Key takeaways

  • Size in order: load → battery → array → controller → inverter.
  • Everything flows from an honest daily watt-hour figure.
  • Battery covers your autonomy; the array refills it each day.
  • A 3,000 Wh/day cabin ≈ a 900 W array and a 12 kWh battery bank.

Step 1 — Total your daily load

An off-grid system is sized from energy, measured in watt-hours per day. List every appliance, multiply its watts by hours used per day, and add them up. The off-grid load calculator does this and also gives the peak load (everything on at once) you'll need for the inverter.

Step 2 — Size the battery bank

The battery stores enough to run your loads through the nights and cloudy days you want to cover (days of autonomy), without discharging past what the chemistry tolerates.

Battery energy (Wh) = Daily Wh × Days of autonomy ÷ Depth of discharge Amp-hours = Battery energy ÷ System voltage

Run it in the battery bank sizing calculator. Use ~50% depth of discharge for lead-acid, 80–100% for LiFePO₄.

Step 3 — Size the solar array

The array has to put back what you took out, during your location's usable sunlight (peak sun hours), with losses.

Array watts = Daily Wh ÷ Peak sun hours ÷ Derate (≈0.75 off-grid)

The solar array sizing calculator turns that into a panel count.

Step 4 — Match the charge controller and inverter

The charge controller has to handle the array's current: MPPT amps ≈ array watts ÷ battery voltage × 1.25 (charge controller calculator). The inverter has to handle your loads: continuous watts ≈ running load × 1.25, with surge headroom for motors (inverter sizing calculator).

The five steps at a glance

StepSizesKey input
1. Load auditDaily Wh & peak WAppliances × hours
2. Battery bankAh / kWhAutonomy & DoD
3. Solar arrayPanel wattsPeak sun hours
4. Charge controllerMPPT ampsArray W ÷ bus V
5. InverterContinuous & surge WRunning & starting load

Worked example: a 3,000 Wh/day cabin

Load is 3,000 Wh/day. Battery: 3,000 × 2 days ÷ 0.5 DoD = 12,000 Wh ≈ 500 Ah at 24 V. Array: 3,000 ÷ 4.5 sun hours ÷ 0.75 ≈ 900 W of panel. Controller: 900 ÷ 24 × 1.25 ≈ 47 A → a 50 A MPPT. Inverter: sized to your peak running load plus motor surge. That's a complete, balanced system.

Frequently asked questions

What order do I size an off-grid system in?

Load → battery → array → charge controller → inverter. Everything flows from the daily watt-hour load.

How much solar and battery for 3,000 Wh/day?

≈900 W of panel and a 12 kWh (~500 Ah at 24 V) bank for 2 days autonomy at 50% DoD — less with LiFePO₄.

Why start with the load?

Battery, array, controller, and inverter are all derived from how much energy you use and how fast — so measure it first.

Educational guide only. Off-grid power carries real electrical and fire risk — verify against the NEC, manufacturer specs, and a licensed electrician or installer before building.